Micro Ion Electrodes
After the success of the Lazar micro pH electrode, Lazar Research Laboratories, Inc.
developed a series of micro ion electrodes which are used today by research
centers worldwide.
Features:
High Sensitivity: Most ions can be measured to below 1
ppm. Some ions such as copper (+2) can be measured down to
the low part per billion range.
Fast response time: Due to membrane design parameters ion
selective have a rapid response to changing ionic concentration.
Response time of 30 seconds is typical.
Broad concentration range: Electrodes will detect ions down to the
low part per million range up to several thousand ppm. Some of the
electrodes will measure up to a concentration of 1 Molar.
Resistant Body: Makes electrodes usable in acids, bases
and some solvents.
Portable: On-the-spot field measurements can be made
without a trip back to the laboratory.
Small Samples: Measures samples as small as 5 ml. Some of the
combination ion electrodes will read down to just 2 ml of liquid.
Quick and Simple Readings: The electrodes can be used with
any portable or laboratory pH/millivolt meter.
Direct Plug: Our electrodes plug directly into your
pH/millivolt meter. No compatibility problems.
All ion selective electrodes in the table below are combination
electrodes where the reference electrode is already included within the body of the
ion selective electrode. Mono electrodes without the reference electrode
are also available upon request. Please contact us for
pricing and delivery. |
Request further product details by email
Scroll further for ion specifications ------------------------------------------->
Electrode type |
Cat. No. |
Cost |
Measurement Range (M) |
Concentration Range(PPM) |
pH Range |
Temp. Range (oC) |
Interferences |
Ammonia |
LGS-136NHM |
$995.00 |
5exp-7 to 1.0 |
0.01 to 17,000 | above 11 | 0 to 50 | volatile aminues |
Bromide |
LIS-146BRCM |
$750.00 |
5exp-6 to 1.0 |
0.4 to 79,000 | 2 to 14 | 0 to 80 | S-, I-, CN-, high levels of CL- and NH3 |
Cadmium * |
LIS-146CDCM |
$750.00 |
1exp-7 to 1exp-1 |
0.01 to 11,200 | 2 to 12 | 0 to 80 | Ag+, Hg+2, Cu+2 |
Calcium * |
LIS-146CACM |
$785.00 |
5exp-6 to 1.0 |
0.2 to 40,000 | 3 to 10 | 0 to 50 | Pb+2, Hg+2, Cu+2, Ni+2 |
Carbon Dioxide |
LGS-136COM |
$970.00 |
exp-2 to exp-4 |
4.4 to 440 | 4.8 to 5.2 | 0 to 50 | Volatile weak acids |
Chloride |
LIS-146CLCM |
$750.00 |
5exp-6 to 1.0 |
1.8 to 35,500 | 2 to 12 | 0 to 80 | S-2, I-, CM-, Br- |
Copper |
LIS-146CUCM |
$750.00 |
1exp-8 to 1exp-1 |
0.0006 to 6,350 | 2 to 12 | 0 to 80 | Ag+, Hg+2 |
Cyanide |
LIS-146CNCM |
$750.00 |
5exp-6 to 1exp-2 |
0.13 to 260 | 11 to 13 | 0 to 80 | S-2, I-, Br-, Cl- |
Fluoride * |
LIS-146FCM |
Out of stock |
1exp-6 to saturated |
0.02 to saturated | 5 to 8 | 0 to 80 | OH- |
Fluorborate * |
LIS-146FLCM |
Out of stock |
6exp-6 to 1.0 |
0.1 to 10,800 | 2.5 to 11 | 0 to 50 | ClO4-, I-, CN- |
Iodide |
LIS-146ICM |
$750.00 |
5exp-8 to 1.0 |
0.006 to 127,000 | 0 to 14 | 0 to 80 | S-2, CN-, Br-, Cl- |
Lead * |
LIS-146LICM |
$750.00 |
1exp-6 to 1exp-1 |
0.2 to 20,700 | 3 to 8 | 0 to 80 | Ag+, Hg+2, Cu+2, high levels Cd+2 and Fe+2 |
Nitrate * |
LIS-146NOCM |
$750.00 |
7exp-6 to 1.0 |
0.6 to 62,000 | 2.5 to 11 | 0 to 50 | ClO4-, I-, CN-, BF4- |
Perchlorate * |
LIS-146PERCM |
Out of stock |
7exp-6 to 1.0 |
0.7 to 98,000 | 2.5 to 11 | 0 to 50 | no significant interferences |
Potassium * |
LIS-146KCM |
$785.00 |
1exp-6 to 1.0 |
0.04 to 39,000 | 2 to 12 | 0 to 50 | Cs+, NH4+ |
Silver/sulfide |
LIS-146AGSCM |
$750.00 |
1exp-7 to 1.0 |
AG = 0.01 to 107,900 S = 0.003 to 32,100 | 2 to 12 | 0 to 80 | Hg+2, Hg+ |
Sodium * |
LIS-146NACM |
$785.00 |
1exp-6 to saturated |
0.2 to 23,000 | 5 to 12 | 0 to 80 | H+, K+, Li+, Ag+, Cs+, Tl+ |
Surfactant * |
LIS-146SURCM |
Out of stock |
1exp-5 to 5exp-2 |
1.0 to 12,000 | 2 to 12 | 0 to 50 | similar types of surfactants |
Thiocyanate * |
LIS-146SCNCM |
Out of stock |
5exp-6 to 1.0 |
0.3 to 58,000 | 2 to 10 | 0 to 80 | S+2, CN-, I-, Br-, S2O3-2, NH3 |
Water hardness * |
LIS-146WHCM |
Out of stock |
1exp-5 to 1.0 |
0.4 to 40,000 (as Ca) | 5 to 10 | 0 to 50 | Cu+2, Zn+2, Mi+2, Fe+2 |
Micro Reference Electrode required for electrodes with * |
Micro Reference Electrode |
LIS-146DJM |
$250.00 |
N/A |
N/A |
2 to 12 |
0 to 80 |
None |
For specific questions or to receive printed literature, send your request by email to
sales@lazarlab.com or call us at 1-800-824-2066, 001-323-931-1204 international, or fax us
at 001-323-931-1434.
Contact us
How to place an order
Prices and specifications subject to change without notice.
|